Logo RIDI Lighting A RIDI Group brand
EN 0

Search result list

RIDI LINIA REFURBISHMENT GEAR TRAYS – THE IDEAL CHOICE FOR REFURBISHING RIDI LINIA CONTINUOUS-ROW LUMINAIRES

With RIDI LINIA refurbishment gear trays, old conventional RIDI LINIA gear trays with T5 and T8 fluorescent lamps can be replaced quickly and efficiently without the need for extensive rewiring or conversion work. By utilising the existing trunking infrastructure, the installation effort becomes quick and simple. This not only saves a considerable amount of time, but also enables a cost-effective and smooth refurbishment of the lighting system with minimal downtime.

REFURBISHMENT IN RECORD TIME – UNCOMPLICATED 1:1 REPLACEMENT

  • Use of the existing trunking infrastructure possible (taking into account the year of production)
  • Fast and efficient solution, without costly rewiring and conversion work

TWO MOUNTING RAIL VARIANTS

Mounting rail cable-bound | Year of manufacture 2003 – 2009 (not metric)

Tapping wired

Flexible mounting rail | Year of manufacture 2009 – 2019 (not metric)

Flexible connector

TWO LENGTHS IN ONE PROTECTION CLASS IP40

For existing products with T5 light source

  • VLG7P SANIERUNG 1486 | Length: 1486 mm
  • VL1GPS SANIERUNG 1486 | Length: 1486 mm

For existing products with T8 light source

  • VLG7P SANIERUNG 1537 | Length: 1537 mm
  • VL1GPS SANIERUNG 1537 | Length: 1537 mm

TWO VARIANTS

switchable (xFlex) - adjustable luminous flux

dimmable (DALI)

TWO BEAM CHARACTERISTICS

B | wide-beam prismatic optics

E | narrow beam prism optics

LATEST LED TECHNOLOGY – MADE IN JUNGINGEN

  • Significant increase in service life thanks to state-of-the-art LED technology
  • Efficiencies of up to 160 lm/W
  • Production at the Jungingen site in Baden-Württemberg, Germany

FURTHER REASONS FOR A 1:1 EXCHANGE

YES TO 1:1 REPLACEMENT

  • New complete luminaires with test marking
  • State-of-the-art LED luminaires with optimised lighting technology
  • Thanks to the use of modern LED luminaires, the failure rate over the entire service life is very low
  • Fulfilment of contemporary lighting quality requirements
  • Demand-led lighting management is possible

NO TO RETROFIT

  • Test markings lose their validity after use of the retrofit light source
  • Light distribution differs, the luminaire can dazzle
  • Lighting quality changes compared to the previous system
  • Efficiency properties are not matched to the existing reflector technology
  • Problems with light dimming and emergency lighting

If you have any questions, please do not hesitate to contact our sales representatives – your personal contact.

TO THE PRODUCTS

LINIA offers solutions and variants for all indoor lighting requirements up to protection rating IP54.
LINIA

REFURBISHMENT EXAMPLE MUNICH TRADE FAIR CENTRE

Annual electricity savings of around 1.5 million kilowatt hours | MORE ON RENOVATION 
This object is already on the Wish list